• AXW1 series intelligent universal type circuit breaker
Details

Product overview

Mixer USES

AXW1 series intelligent universal type circuit breaker, it is our company according to the market demand and development, the development of one of the new type of circuit breaker. Is mainly used for 400/690 v ac 50 hz, rated voltage, rated current 630 a ~ 6300 a power distribution network, used for distribution power and protect circuit and power equipment from overload, short circuit, under voltage, grounding fault and harm; With multiple protection function, can realize the selective protection and movement precision, quality and reliability of power supply, the products are widely used in the modern distribution network.

Mixer features

Using the latest intelligent tripping device, the comprehensive technology solutions, has self-checking, measure, test, monitoring and display records and communication functions, such as open communication structure, standard communication interface can be controlled by the computer cluster to realize the "four wave".

Conventional progresses for line, can also be next in line.

Three-dimensional split type layout, compact structure, small volume, high breaking capacity.

Arcing distance is zero, high safety.

The whole module structure, easy installation and maintenance, do not need to make any adjustments.

In pieces accord with a standard

IEC60947-1 and 14048.1 GB "low-voltage switchgear and control equipment Part 1: general rules"

IEC60947-2 GB and 14048.2 "low-voltage switchgear and control equipment Part 2: circuit breaker.

Mixer type

Installation type: type, drawer

Operation mode: electric operation and manual operation (manual operation is mainly used for repair and maintenance)

The number of: three pole, quadrupole

Normal working conditions in pieces

Ambient air temperature is not more than + 40 ℃ and not lower than 5 ℃, 35 ℃ and average no more than 24 h + (special orders except)

The altitude does not exceed 2000 m installation site.

Atmospheric conditions, air relative humidity in the surrounding air temperature to + 40 ℃ not more than 50%;

At low temperature can have higher relative humidity;

The wettest month average maximum relative humidity is 90%, while the average minimum temperature of the month to + 25 ℃, and considering the due to temperature change in any condensation on the product surface.

Normal installation conditions in pieces

The user in accordance with the requirements of the manual for installation, the vertical slope of the circuit breaker is not more than 5 degrees.

Install the category